Agilent Technologies J3972A, J3919A manual Connecting the Probe

Models: J3919A J3972A

1 189
Download 189 pages 36.38 Kb
Page 73
Image 73

Installation

Connecting the Probe

Use the following procedures to connect the probe’s RJ-45 connector to a 10MB/s or 100MB/s Ethernet network for telemetry communications. Never use both the AUI and RJ-45 connectors.

1.Connect the probe’s 10Base-T/100Base-TX (RJ-45) port, located on the rear panel, to the network using a category 5 cable. Figure 3-5 on page 54 shows how to connect the probe to a 10Base-T or 100Base-TX network.

2.Select RJ-45as the Physical Connector parameter from the Modify/View Interface Values menu.

3.If you are connecting to a device that supports the auto-negotiation protocol, select Auto Negotiate for the Link Speed parameter from the Modify/View Interface Values menu. Otherwise, select 10MB/s (for 10MB/s Ethernet) or 100MB/s (for 100MB/s Ethernet).

The probe will automatically negotiate the speed of the interface if the Link Speed parameter is set to Auto Negotiate and if the connected device supports the auto-negotiation protocol.

4.If you selected 10MB/s or 100MB/s for the Link Speed parameter, you must also select Half-Duplexfor the Full/Half Duplex parameter from the Modify/View Interface Values menu.

53

Page 73
Image 73
Agilent Technologies J3972A, J3919A manual Connecting the Probe