NOTE

Local Terminal Configuration

Using a Local Terminal

A warm start resets all data collected by the probe. A cold start resets all data collected by the probe and also resets any user-configuration information, such as history studies, filters, and alarms to their default values. Refer to Chapter 5 “Probe Operation” for more information on what is reset by warm and cold starts.

After the probe restarts (boots), it operates normally using the new configuration information. The warm start or cold start occurs immediately and there is no visual indication of when it finishes.

4.If you are performing the initial probe configuration, prepare the probe for installation by disconnecting the power cord. You will not lose your initial configuration information.

Modify/View Serial Port Settings

You can view or modify the probe’s serial port settings by entering the Serial Port number into the Modify/View Interface Values Menu’s Port parameter. The Serial Port configuration parameters are then shown along with their current settings.

Use the following procedure to configure the probe’s serial port:

1.Enter the probe’s Serial Port number into the Modify/View Interface Values Menu’s Port parameter as shown in Figure 2-5 on page 26. Refer to the “Display Interface Summary” on page 36 to determine the Serial Port number.

37