Installation

Starting the Probe

Starting the Probe

NOTE

If you are using the Bootp server method of configuration, do not attach the power

 

cord to the probe until told to do so in Chapter 4 “Bootp Server Configuration”.

 

If you used the local terminal method of configuration, attach the power cord to

 

 

the probe. The probe does not have a power switch, but is powered on when

 

power is attached. When powered on or reset, the probe runs self-tests and

 

transmits ICMP echo frames to the default gateway for the purpose of allowing

 

the probe to be discovered by the routers (ARP cache). The probe transmits four

 

ICMP echo request packets about 10 seconds after booting and again every

 

autodiscovery echo interval. Refer to Chapter 5 “Probe Operation” for more

 

information on resetting the probe.