Agilent Technologies J3919A, J3972A manual Connecting the Probe

Models: J3919A J3972A

1 189
Download 189 pages 36.38 Kb
Page 82
Image 82

Installation

Connecting the Probe

“Install the Management Station Modem” below

z“Install the Probe’s Modem” on page 63

“Configure the Management Station and the Probe” on page 63

Figure 3-13: The Probe’s Modem Connection

Install the Management Station Modem

You need the following list of equipment to install the management station’s modem:

Hayes-compatible 300 to 38.4 K baud modem

zRS-232C (straight through) modem cable

Modular phone cable with RJ-11 connectors or equivalent

Use the following procedure to install the management station’s modem:

CAUTION Turn off all equipment prior to making cable connections.

1.Place the modem close enough to the management station to not violate the 50-foot RS-232C distance limitation.

2.Connect the RS-232C cable from the modem’s RS-232C port to the management station’s serial port. Take care in selecting the appropriate serial port on the management station (COM1 or COM2, for example).

3.Connect the RJ-11 modular phone cable from the modem To Line port to the telephone jack.

62