Probe Operation
Restarting the Probe
Cycling Power
A power outage or cycling power to the probe causes a warm start. The probe does not have a power switch; therefore, cycling the power consists of disconnecting and reconnecting the power cord.
Selecting the Warm Start Menu Item
Use the following procedure to warm start the probe using the probe’s Main Menu:
1.Connect a local terminal (or a PC emulating a terminal) to the probe. Refer to Chapter 2 “Local Terminal Configuration” for information on connecting a local terminal.
2.Press the CONFIG button once (on the back of the probe) to place the probe into the configuration mode. Use a narrow, pointed object (like a pen) to press the recessed CONFIG button. The probe then displays its Main Menu on the terminal. Figure
Main Menu - Revision
1.Modify/View configuration values
2.Modify/View security values
3.Modify/View interface values
4.Display interface summary
5.TFTP Download new firmware
6.XMODEM Download new firmware
7.Warm start and Exit
8.Cold start and Exit
Figure 5-1: The Probe’s Main Menu