Local Terminal Configuration
Using a Local Terminal
28
It requires the IP Address, Subnet Mask, and Default
Gateway IP Address fields. The following apply to Telemetry
ports:
HP OpenView can discover the interface
The interface is IP addressable
The interface responds to RMON-1
The interface will transmit all traps from th e probe
The interface will transmit all extended RMON packets
sample from Monitor-only ports, Monitor/Transmit port s.
IP Address Press 3 and enter the IP address for the probe. If the IP
address is 0.0.0.0, the probe will transmit Bootp Requests
for configuration information (including IP address) over the
network. This does not apply to ports configured as Monitor-
Only.
Default Gateway Press 4 and enter the default gateway IP address for the probe
IP Address (optional).
Subnet Mask Press 5 and enter the subnet mask for the probe.
Physical Press 6 and select the physical connector. The menu only
Connector shows the physical connectors that are available. You can use
the RJ-45 or AUI connector. If you select AUI, items 7 and 8
(Link Speed and Full/Half Duplex) are no t a vailable. AUI is
10MB/s half-duplex.
CAUTION If you manually selected the Link Speed, be careful to configure it correctly. If
you configure the Link Speed for 100 MB/s and you connect the probe to a
10MB/s network, the probe will generate 100% utilization for that segment.
Link Speed Press 7 and select the Link Speed as Auto Negotiate,
10MB/s, or 100MB/s. When you configure this parameter for
Auto Negotiate, the item 8 parameter (Full/Half Duplex) is
not available.