22-12 Sm artSwit ch 1800 4.0 U ser Gui de, Rev 01
Meaning: The BSC device has experienced a problem that caused it to send a
request to send a dump to the port.
Action: Check the device.
432. Node Un der Re m ot e Co ntrol
Severity: 4
Meaning: The SmartSwitch 1800 is under contr ol of a remote C abletr on fram e
relay access device (SmartSwitch 1800, FRM, FRX4000,
FRX600 0) or asyn c ter minal .
Action: None.
433. Remote Control Released
Severity: 4
Meaning: An operator has relinquished remote control (see event 432) of the
local SmartSwitch 1800.
Action: None.
434. Remote Control CX N Clr cc = ā€œnā€ dc = ā€œnā€
Severity: 4
Meaning: A remote control connection (see event 432) was cleared.
Action : Depe nds on t he cause . (See Appendix B for a list of codes.)
435. LG Buffer MALLOC Problem PKTs Lost
Severity: 2
Meaning: This applies to a debug tool used by service personnel, and will not
appear under normal operation.
Action: None.
436. RCV Unknown Event C ode from Net.
Severity: 2
Meaning : A n unknow n event w as rece ived f rom th e n etwor k.
Action: None.
437. RCV Invalid Event F ormat from Net.
Severity: 4
Meaning: The node has received an event with an invalid format.
Action: None.
439. Database Error, Access R estricted
Severity: 1
Meaning: The database is inconsistent with what the software expects.
Action: Contact Cabletron Systems Technical Support. (See page 22-4.)