Chapter 5Loading Protocols
Although a SmartSwitch 1800 is shipped with a set of protocols already installed, a
file must be configured to properly load them into the software.
To access Protocol configuration, press [A], then [B] from the Main M enu. Then:
To displ ay a lis t of con fi g ured a nd load ed prot ocols , pres s [A]. A ne wl y add ed
protoc ol is disp layed a s Configured
until the node i s rebooted, at which time th e
protocol will be displayed as Loaded.
X.25 is always loaded, and will not b e displayed. The information is
taken from the configuration file, which does not allow configuring
X.25. This prevents the po ssiblility of deleting X.25, w hich is a nec-
essary protocol for use by internal SmartSwitch 1800 traffic.
To displ ay a ta bl e of mem ory usa ge, pre ss [C]. This information, in conjuction
with information in the release notes, can help in planning the number of pro-
tocols to run.
To add or remove a protocol, press [B]. This will display a screen similar to
Figure 5-1.
Figure 5-1 Protocol Configuration Menu
[A],[B],[B] from Main Menu
The parameters RLP, Status, RLP Type, and Line Interface Card 1/2 are irrel-
evant, and are displayed only because some of the SmartSwitch 1800
software code is shared with the FRX6000, which uses the information.
Node Name=nodexyz
RLP Configuration
* RLP: 1 * Status: Installed *Memory Configuration: 8 Meg
* RLP Type: RLP
* Line Inter f ac e Card 1: UNI VERSAL
* Line Inter f ac e Card 2: VO ICE Config ured Loaded
F Protocol 1: FR FR
G Protocol 2: IP I P
H Protocol 3: VOICE VOICE
I Protocol 4: SDLC SDLC
J Protocol 5: BSCI BSCI
K Protocol 6: None
L Protocol7: None
M Protocol 8: None
N P rotocol9: None
Option: