11-2 Smart Switch 1800 4. 0 User Guide , Rev 0 1
Configuring BSC Batch Ports
Once the necessary Node (Chapter 4) and protocol (Chapter 5) parameters have been
configured, press [A] at the Port Configuration Menu (or [A], [C], [A] f r om the Main
Menu. When prompted, enter a port number (or press [Enter] to accept the default of
0). Valid port numbers depend on the model of SmartSwitch 1800—see po rt locations
on p age 6- 1.
The display for an existing port will show the configured parameter values, while the
display for a new port will show d efault database values. (S ee Table 11-1 on page 11 -
3.) The following figure is an example of an existing port.
Figure 11-1 BSC Batch Port Record
[A],[C],[A]
from Main Menu
After making any changes, be sure to press [F7] to up date the
system memory. Otherwise, the changes will not take effect until
the next re-boot of the SmartSwitch 1800.
Pressing [J] lists mo re parame ters, and pressing [K] displays a screen similar to the fol-
lowing. (All BSC Batch parameters are listed in Table 11 -1.)
Node Name=nodexyz
BSC Batch Port Parameters (screen 1 of 2)
* Port: 1 Link State: Linkup
*I/O:V.35 Database System Memory
A Port Type BSC Batch BSC Batch
B Physical Port Interface V.35 V.35
C Blocke d P ort Fl a g N N
D Line Speed 9600 bps 9600 bps
E Retransmission Period (ms) 2000 2000
F Maximum Retransmissions 5 5
G Maximum Bytes per Frame 4105 4105
H Generate Clock Y Y
I Rcv Clock (TT) from D TE N N
J Batch Parameters - Screen 2
K Subscriber Information - Screen 3
Option: