15-8 Smart Switch 1800 4. 0 User Guide , Rev 0 1
Configuring IPX Filter Applications
IPX Filter Applications determine how filters will be used at the interface. To review
existing applications, press [C] at the Configure Filter Definitions and Applications
Menu (o r [A], [A], [E], [F], [C] from the Main Menu) . To config ure an app licati on, pre ss
[D] at the Configure Filte r Definitions and Applications Menu. When prompted, enter:
Interface number: 0–63. (The def ault is 0.) This identifies the virtual interface.
Filter Category:
0 = RIP, 1 = SAP, 2 = Packet, 3 = RIP Router. (T he default i s 0.)
Direction: i (inbound) or o (outbound). (The default is o.)
Any other requested information, referring to Table 15 -6.
Figure 15-3 Typical IPX Filter Applications Record
[A], [A ], [E ], [F] ,[ D] fro m Main Menu
Up to 100 filters can be configured, displayed over 9 "pages" (screens).
When finished configuring filter definitions and applications, perform an on-line
update to make the changes effective immediately. Press [E] at the Filter Definitions
and Applications Configuration Menu. The changes will be sent to the software.
IPX Filter App lication s
* Inter fac e N u m b er 2
* Filter Category 0 RIP
* Directio n I–Inbo und
APermit Y
B F ilter Application 1 0
C Filter Application 2 0
D Filter Application 3 0
E F ilter Application 4 0
F Filter Application 5 0
G Filter Application 6 0
H Filter Application 7 0
I Filter Application 8 0
J Filter Application 9 0
K Filter Application 10 0
2 Page 2