16-12 Sm artSwit ch 1800 4.0 U ser Gui de, Rev 01
Configuring Bridge Ports
A Bridge port is a SmartSwitch 1800 LAN interface or frame relay port that will
operate as a bridge connection to the LAN or WAN.
Press [C] at the IP/LLC2/BRIDGE/I PX Inter faces Confi guratio n Menu to displ ay con-
figure d B ridge ports .
Figure 16-4 Bridge Ports Display
[A],[C],[E],[C] from Main Menu
These interfaces can be used for either LLC2 or Bridging. Also note
that the RLP column is irrelevant on the SmartSwitch 1800.
To configure an interface, press [D] at the IP/LLC2/BRIDGE/IPX Interfaces Config-
urati o n Me nu . Wh en prompted for an Interface Number (which is merely a sequential
number to identify the interface):
If modifying an existing record, enter the interface number: 0–95.
Do not configure more than one interface per DLCI on a port.
If creating a new record, press [Enter], which will automatically specify the next
available sequential interface number.
The display depends on the interface; the following figure shows an example, and
Table 16 -8 lists the parameters for all interface types.
Node Name=node_xyz
Review Bridge Ports/LLC2 Interfaces
-------------------------------------------------------------------------------------------------------
Interface Number Type RLP Port DLCI Format
-------------------------------------------------------------------------------------------------------
0 Ethernet
1 Frame Relay 0 1 30 Native LLC-2
2 Frame Relay 0 1 31 8025_SRB
3 Frame Relay 0 1 32 8025_SRB
4 Frame Relay 0 1 33 8023_TB
PgUp, PgDn, F3:Exit, F9:Stop Remote, F10:Abort