SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide Switch Configuration
1200, 2400, 4800, 9600, 19200, 38400, 57600, or Autobaud. The default value for
this parameter is 9600. Make sure that your terminal emulator baud rate matches
the console baud rate you set.
Creating a Console Session Using a Modem
Use the Serial Link Configuration menu to configure the SmartStack STS16-
20D/STS16-20R in order to communicate with a console via a modem.
Set your modem according to the following table:
Caution: Some modems use slightly different names for the options. It is important
that your modem be configured correctly. The settings shown in italics are
particularly important. If your modem is not configured correctly, the connection
may cause the SmartStack STS16-20D/STS16-20R to reset.
Start the console by pressing ENTER. If a Telnet session is active, press ENTER at
the console to terminate the Telnet session and press ENTER again to start the
console session.
Stopping the Console Session
Pressing CTRL-P returns the console session to the main menu, and pressing CTRL-
B returns to the greeting menu.
Setting Value
Echo Off
Result codes Off
Wait for connection 45 seconds
Pause between calls 6 seconds
Drop DTR between calls Yes
Send CR between calls Yes
Auto baud detect On
Send init if CD high Yes
Maximum dial attempts 999
Table 14. Modem Settings