Cabletron Systems STS16-20R, STS16-20D manual 151, Execute name Download/Upload

Models: STS16-20R STS16-20D

1 258
Download 258 pages 63.79 Kb
Page 165
Image 165

151

Note! When upgrading the boot code, append the string *boot to the filename when entering the filename. For example, to download the 2.3 bootcode to the switch, type the following:

main image download filename: STS_230.bt*boot

Execute <name> Download/Upload

This command is displayed on the sub-screens that are opened from the TFTP Download/Upload screen.

The command Execute <name> Download/Upload initiates the download or upload for a single switch only. On a locally attached console, the screen displays the block it last received from the server (block 0 if no reply has been received) until the last packet arrives. The switch does not attempt to load any of the image into flash memory until it receives the final packet. Therefore, if interrupted or cancelled for any reason before the last packet, the previous system image remains intact in flash memory.

Once the last packet has arrived, the switch immediately begins clearing flash memory and loads it with the new image.

The switch will continue to use its previously loaded software until its next reset by whatever means. The newly stored image is not functional until a reset is performed.

When downloading configuration, all configurable parameters will be replaced with this new configuration, the message log will be cleared and the switch must be reset immediately after.

While uploading configuration files, the switch can continue normal operation. Note that some TFTP servers requires that the file exist before it will allow uploading. The switch will append the box number (.#) to the filename, that is, stand-alone boxes will append “.1”.

Note: Be careful - if the process is interrupted during this time, the stored image may be corrupted and the SmartStack STS16-20D/STS16-20R will not be able to boot normally! If this happens, it is necessary to download the switch via its Out- of-Band Management port since the system boot image does not contain software capable of operating the network hardware of the switch or interpreting IP and TFTP protocols. During this fairly short vulnerable period of time, the diagnostic LED on the switch blinks to indicate the clearing (slow blink) and reloading (faster blink) of flash memory. The screen also displays messages indicating these events.

Switch Configuration

SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide

Page 165
Image 165
Cabletron Systems STS16-20R, STS16-20D manual 151, Execute name Download/Upload