4.2.13Dead Battery Warning (Output)

(1)Function

The signal will be output when the voltage of the encoder back-up battery or memory back-up battery becomes dangerously low.

(2)Terminal number

No. 14 of connector CN10.

(3)Usage

The signal is used to check the timing of battery replacement (lowering of the battery voltage).

(4)ON conditions

The signal will be turned ON when the voltage of the encoder back-up battery or memory backup battery becomes dangerously low.

Caution: Any error of ERROR64A1 to 64A6 indicating the dead encoder back-up battery or ERROR6103 informing the dead memory back-up battery will be displayed on the operating panel and the teach pendant.

(5)OFF conditions

The signal will be turned OFF when the power is turned ON after the dead battery was replaced.

 

 

Power ON

 

Power OFF

 

Power ON

 

Power OF

F

Power ON

 

Robot power ON state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The voltage of the encoder backup battery or memory back-up battery becomes dangerously low.

Dead battery warning output

Battery replaced

Dead Battery Warning Output