3.2.6Normal CPU (Output)

(1)Function

The signal outputs to the external device that the Robot Controller CPU (hardware) is normal.

(2)Terminal number No.1 of connector CN10.

(3)Usage

The signal is used to light the Robot Controller external operating panel error indicator lamp.

The signal is used when a normal CPU SIGNAL is turned OFF because of an error and the PLC corrects it.

(4)ON conditions

The signal will be turned ON by the hardware when the Robot Controller CPU operates normally with the power turned ON.

(5)OFF conditions

The signal will be turned OFF by the hardware when the CPU does not operate normally.

Caution: The OFF state of this signal indicates that the Robot Controller internal arithmetic circuit may be damaged. Therefore, ROBOT ERROR, ERROR NUMBER, and other outputs may not be correct.

Power ON (CPU operating properly)

Normal CPU output

Abnormal CPU (hardware error)

Normal CPU Output