3.2.9Dead Battery Warning (Output)

(1)Function

The signal will be output when the voltage of the encoder back-up battery or memory back-up battery becomes lower than acceptable.

(2)Terminal number No.8 of connector CN10.

(3)Usage

The signal is used to check the timing battery replacement. For example, the battery voltage becomes lower than acceptable.

(4)ON condition

The signal will be turned ON when the voltage of the encoder back-up battery or memory back-up battery becomes lower than acceptable.

Caution: The operating panel shows any of ERROR64A1 to 64A6 when the encoder back-up battery voltage is low. Meanwhile, the teach pendant shows ERROR6103 when the memory back-up battery voltage is low.

(5)OFF condition

The signal will be turned OFF when the power is turned ON after the dead battery was replaced.

Power ON

Robot power ON state

Power OFF Power ON Power OFF

Power ON

The voltage of the encoder backup battery or memory back-up battery becomes dangerously low.

Dead battery warning output

Battery replaced

Dead Battery Warning Output

35

Page 55
Image 55
Denso RC5 manual Dead Battery Warning Output