Denso RC5 manual 151, Modifying the Shielding Wire Example

Models: RC5

1 176
Download 176 pages 51.26 Kb
Page 171
Image 171

If you do not use optional cables listed on the previous page, use the recommended connectors and cables listed below.

Recommended Connectors for I/O Cables and Cable Standards

Connector

Connector

Cable Standards

Remarks

name

model/manufacturer

 

 

 

 

 

 

 

PCR-E68FS connector

UL2789 - With shield

Caution: Be sure to modify the

OUTPUT

PCS-E68LA cover

Equivalent to AWG28-68P

shielding wire at the end of the

cable to be used, as shown

Honda Communications

 

 

 

below. Without this modification,

 

Industry Co., Ltd.

 

the robot may malfunction due to

 

PCR-E20FS connector

UL2789 - With shield

noise.

HAND I/O

PCS-E20LA cover

Equivalent to AWG28-20P

 

Honda Communications

 

 

 

 

 

 

Industry Co., Ltd.

 

 

 

 

 

 

 

PCR-E50FS connector

UL2789 - With shield

 

INPUT

PCS-E50LA cover

Equivalent to AWG28-50P

 

Honda Communications

 

 

 

 

 

 

Industry Co., Ltd.

 

 

 

 

 

 

 

DE-9P connector

UL2405 - With shield

 

I/O

DE-C4-J6 cover

Equivalent to AWG20-2P

 

POWER

Japan Aviation

 

 

 

Electronics Industry, Ltd.

 

 

 

Crimp terminal

 

Vinyl tube

Braided

 

shielding wire

Shielding wire

I/O cable

 

The connector shell should be made of conductive metal.

Fasten to the connector

I/O power connector

Vinyl tube

Modifying the Shielding Wire (Example)