3.2.3External Mode (Output)

(1)Function

The signal outputs to the external device that the robot is in external mode.

(2) Terminal number

No.7 of connector CN10.

(3) Usage

Starting the program from the external device requires an EXTERNAL MODE SWITCHING BY MODE SWITCHING COMMAND input and a PROGRAM START BY PROGRAM OPERATION COMMAND input. The signal is used to confirm that the robot is in external mode.

(4) ON conditions

The signal will be turned ON under the following conditions. The external mode is selected on the teach pendant.

The EXTERNAL/INTERNAL is input on the operating panel in AUTO MODE and in the INTERNAL CONTROL ON state.

ƒThe EXTERNAL MODE SWITCHING BY MODE SWITCHING COMMAND is input from the external device.

(5)OFF conditions

The signal will be turned ON under the following conditions.

• When internal mode is selected on the teach pendant.

When the mode selector switch of the teach pendant is set to MANUAL or TEACH CHECK in external mode.

ƒWhen EXTERNAL/INTERNAL is input on the operating panel in AUTO

MODE and in the INTERNAL CONTROL OFF state.

When ROBOT STOP is input.

When ROBOT FAILURE is outputted.

Caution: The signal will not be turned OFF with INSTANTANEOUS STOP, STEP STOP or CYCLE STOP.

When an Enable Auto input is turned OFF.

When the mode is switched to external mode on the teach pendant.

When EXTERNAL/INTERNAL is input on the operating panel.

When a MODE SWITCHING COMMAND (EXTERNAL MODE SWITCHING)

is input from an external device.

External mode

output

When internal mode is selected on the teach pendant.

When the mode selector switch of the teaching pendantis set to MANUAL or TEACH CHECK.

When EXTERNAL/INTERNAL is input on the operating panel.

ROBOT STOP or ROBOT ERROR

When an Enable Auto input is turned OFF.

External Mode Output

29