4.2.10Normal CPU (Output)

(1)Function

The signal outputs to the external device that the CPU (hardware) of the Robot Controller is normal.

(2)Terminal number

No. 1 of connector CN10.

(3)Usage

The signal is used to light the Robot Controller error indicator lamp of an external operating panel.

The signal is used when the NORMAL CPU signal is turned OFF because of an error and the PLC corrects it.

(4)ON conditions

The signal will be turned ON by the hardware when the CPU of the Robot Controller operates normally with the power turned ON.

(5)OFF conditions

The signal will be turned OFF by the hardware when the CPU does not operate normally.

Caution: The OFF state of this signal indicates that the internal arithmetic circuit of the Robot Controller may be damaged and ROBOT ERROR, ERROR NUMBER and other outputs may not be correct.

Power ON (CPU operates properly)

Normal CPU output

CPU error (hardware error)

Normal CPU Output

79