4.4.5Program Reset (Input)

(1)Function

By turning ON (short) this signal, any program can be forcibly executed from the beginning in a step-stopped state and a suspended state.

Caution: Generally, a step-stopped or suspended program resumes from where it stopped.

(2)Terminal number No.24 of connector CN8.

(3)Input conditions and operation When issued with the Program Start

The figure below shows the input conditions and an operation timing chart.

Use the program reset signal together with a program No. select signal, and input it before the program start signal (1 msec. or more).

ƒTurn OFF the program reset signal after the robot starts to operate

(after a program start reset signal is output).

A program No. select signal is required to execute the same program number as the suspended one from the beginning.

Input Conditions and Operation of Program Reset Signal

98

Page 118
Image 118
Denso RC5 manual Program Reset Input, Input Conditions and Operation of Program Reset Signal