Denso RC5 manual Wiring Notes for Robot Controller I/O Connectors PNP Type, 148

Models: RC5

1 176
Download 176 pages 51.26 Kb
Page 168
Image 168

6.3Wiring Notes for Robot Controller I/O Connectors (PNP

type)

After the wiring of the controller's I/O connectors is completed, check the following before turning ON the power:

Check point (1)

Using a circuit tester, check across the "+24V terminal" and "0V terminal" of each connector and across the "E24V terminal" and the "E0V terminal" to see that there is no continuity. See the figure below and the table given on the next page.

Caution: If the connector wiring between the robot controller's "+24V terminal" and "0V terminal" and between the "E24V terminal" and the "E0V terminal" is shorted, damage to the power circuit of the Robot Controller will result.

Check point (2)

Using a circuit tester, check across "each signal Output terminal" and "+24V terminal" or "E24V terminal" of each connector to see that there is no continuity. See the figure below and the table given on the next page.

Caution: If the wiring between "each signal Output terminal" and "+24V terminal" or "E24V terminal" of each connector is shorted, damage to the Output circuit and power circuit of the robot controller will result.

Caution: Wind adhesive vinyl tape around all ends of the unconnected wiring of each connector to prevent them from contacting other wiring and parts, which results in shorting.

 

 

Circuit tester

Robot

 

 

controller

“+24V terminal” and

External

 

“E24V terminal” of the

device

 

controller

 

 

 

“0V terminal” and

 

 

“E0V terminal” of the

 

 

controller

Checking Example

148

Page 168
Image 168
Denso RC5 manual Wiring Notes for Robot Controller I/O Connectors PNP Type, 148