3.2.2Auto Mode (Output)

(1)Function

The signal outputs to the external device that the robot is in auto mode.

(2)Terminal number No.6 of connector CN10.

(3)Usage

Starting the program from the external device requires an EXTERNAL MODE SWITCHING BY MODE SWITCHING COMMAND input and a PROGRAM START BY PROGRAM OPERATION COMMAND input. The signal is used to monitor the auto mode output signal and determine whether to execute the command.

(4)ON condition

The signal will be output when the robot enters auto mode by setting the mode selector switch of the operating panel or teach pendant to AUTO.

(5)OFF conditions

The signal will be turned OFF under the following conditions.

The mode selector switch of the operating panel is set to MANUAL or the teach pendant is set to MANUAL or TEACH CHECK.

The Enable Auto OFF is input..

(Note: The signal will not be turned OFF in the pendantless state described in the OPTIONS MANUAL, Chapter 1, Subsection 1.3.3.)

Caution: The signal will not be turned OFF with INSTANTANEOUS STOP, STEP STOP or CYCLE STOP commands.

When the mode selector switch of the operating panel or teach pendant is set to AUTO.

Auto mode output

When the mode selector switch of the operating panel is set to MANUAL or that of the teach pendant is set to MANUAL or TEACH CHECK.

When Enable Auto OFF is input