Denso RC5 manual System I/O Signals Standard Mode

Models: RC5

1 176
Download 176 pages 51.26 Kb
Page 46
Image 46

Chapter 3

System I/O Signals Standard Mode

3.1Types and Functions of System Output Signals (Standard

Mode)

The table below lists the system output signals used in standard mode.

Types and Functions of System Output Signals to be Used in Standard Mode

Application

Signal name

Function

 

 

 

 

Robot initialization

Outputs when preparations for operation are ready to

 

complete

start.

 

 

 

Start-up

Auto mode

Outputs when the robot is in Auto mode.

 

 

 

External mode

Outputs when the robot is in external mode.

 

 

 

 

Servo ON

Outputs when the power to the motor is turned ON.

 

 

 

Program execution

Robot-in-operation

Outputs when the robot is in operation (the program is

being executed).

 

 

 

 

 

 

Normal CPU

Outputs when the CPU (hardware) of the Robot

 

Controller is normal.

 

 

 

 

 

 

Robot failure

Outputs when a serious error, such as a servo error

 

and a program error, occurs.

Error/Warning

 

 

 

Robot warning

Outputs when a slight error occurs.

 

 

 

 

 

Dead battery warning

Outputs when the voltage of the encoder back-up

 

battery or memory back-up battery dangerously low.

 

 

 

 

 

Continue start

Continue start

Outputs when Continue Start is enabled.

permitted

 

 

 

 

 

Safe start function

SS mode

Outputs when the robot is in SS mode. Refer to the

SETTING-UP MANUAL, Chapter 3, Subsection 3.4.6

 

 

"SS (Safe Start) Function."

 

 

 

Emergency stop

Emergency stop

Outputs from a contact exclusively designed for an

emergency stop circuitry.

 

 

 

 

 