3.4.5Interrupt Skip (Input)

(1)Function

If this signal is turned ON (shorted) during execution of the robot operation command, within the range between INTERRUPT ON and INTERRUPT OFF in the program, the correct step operation will immediately stop and the next step will start.

Caution: For further information about the INTERRUPT ON and OFF commands, see the PROGRAMMER'S MANUAL (I), Chapter 12, "12.3 INTERRUPT ON/OFF (Statement)."

For further information about the robot operation command, see the PROGRAMMER'S MANUAL (I), Chapter 12, "Robot Control Statements."

(2)Terminal number No.9 of connector CN8.

(3)Usage

See the PROGRAMMER'S MANUAL (I), Chapter 12, "12.3 INTERRUPT ON/OFF."

(4)Input conditions and operation

If this signal is turned ON (shorted), the robot will immediately stop the current operation and start executing the next step.

 

 

INTERRUPT ON

 

Robot status

Command

Operating halfway

Next operation

 

 

 

 

 

 

 

50 ms. or more required

Interrupt skip signal (input)

ON (shorted)

 

 

 

 

OFF (open)

 

 

 

Input Conditions and Operation of Interrupt Skip

43

Page 63
Image 63