6.2.4 Emergency Stop Circuit

The following figures show the examples of configuration and connection of emergency stop circuit for the robot controller.

The red mushroom-shaped switch provided on the robot controller front panel, on the teach pendant, or on the operating panel can be used as a switch for stopping the equipment in case of emergency.

6.2.4.1Standard type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Robot controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F1

 

 

 

 

 

 

 

 

 

 

 

 

 

CN7

 

 

 

Internal 24V

 

 

 

 

 

 

 

Fuse (1.3A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse (1.3A)

 

Emergency stop circuit

 

 

 

Internal 0V

 

 

 

F2

 

 

 

 

 

 

 

 

 

 

(prepared by customers)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F9

 

 

Emergency

 

CN10

 

 

 

 

Fuse (0.3A)

 

 

Stop +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emergency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal

F8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24V

 

 

 

 

CN8

 

 

 

 

 

 

 

 

 

Fuse (1.3A)

 

 

 

 

 

 

 

 

 

 

Robot stop switch circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(prepared by customers)

Emergency stop switch

 

 

on the front panel of the

 

 

Input

controller

 

 

 

 

 

 

 

 

CN5 Teach pendant

Emergency stop switch on teach pendant

Internal 0V

(When the internal power source is used)

Robot controller

 

 

 

 

Emergency stop circuit

 

Emergency

 

 

(prepared by customers)

 

 

 

 

 

 

F9

CN10

 

 

 

Fuse (0.3A)

Stop +

 

 

 

External 24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emergency

Stop -

Internal

24V F8

Fuse (1.3A)

Emergency stop switch on the front panel of the controller

Output

External 0V

CN8

Robot stop switch circuit (prepared by customers)

Input

 

 

Teach pendant

CN5

 

 

 

 

 

 

Emergency stop switch on teach pendant

Internal 0V

(When an external power source is used)

Emergency Stop Circuit (Standard type)

144

Page 164
Image 164
Denso RC5 manual Emergency Stop Circuit, 144