4.2.7Program Start Reset (Output)

(1)Function

This signal is output to the external device when the robot receives a start signal from the external device and starts to operate.

(2)Terminal number

No. 6 of connector CN10.

(3)Usage

The signal is used to prompt the external device to receive information that the robot program has started to run, and to process subsequent sequence programs.

The signal is used as a condition to turn OFF the PROGRAM START signal sent from the external device to the robot.

(4)ON conditions

The signal will be turned ON immediately after the robot program starts to run, as shown below.

(5)OFF conditions

The signal will be turned OFF automatically when the PROGRAM START signal sent to the robot is turned OFF.

Robot status

Single-cycle operation

Single-cycle operation

 

Program start signal (input)

ON (shorted)

 

 

OFF (open)

 

Program start

 

 

Reset (output)

 

 

Program Start Reset Output ON Condition