ƒWhen the status of the program start signal is switched from OFF to ON with the program immediately stopped, the program will resume from the suspended step and stop at the cycle end.

Robot status

 

Single-cycle operation

 

 

Performing

 

Operating

 

 

On halt

remaining

 

halfway

 

operation

Program start

ON (shorted)

 

 

signal (input)

OFF (open)

 

 

Instantaneous stop

ON (shorted)

 

 

signal (input)

OFF (open)

 

 

Program Start Operation-3

Caution: To cancel the execution of the remaining steps of an instantaneously stopped program and start it from the beginning, input a program reset signal, a program No. select signal and a program start signal at the same time. For further information, refer to Subsection 6.4.5 "Program Reset (Input)".

94

Page 114
Image 114
Denso RC5 manual Program Start Operation-3