Library Information

For each parameter, the SCSI Mode Parameters screen shows the current (Cur), default (Def), and saved (Sav) values:

￿The current value is the value currently active. It is either the power-on default or a temporary value set by the latest MODE SELECT command.

￿The default value is the original value set at the factory.

￿The saved value is the value specified as the power-on default by a MODE SELECT command. After a saved value has been specified with a MODE SELECT command, this value takes effect each time you power on the library.

The table below describes the items on the SCSI Mode Parameters screen.

SCSI mode parameters

CHM Addr*

The element address of the cartridge handling mechanism (CHM).

 

 

Stor Addr*

The element address of the first storage location, which is the fixed

 

cartridge slot. See Appendix D for the complete numbering scheme.

 

 

DriveAddr*

The element address of the first tape drive (the top tape drive). The

 

remaining tape drives are numbered consecutively.

 

 

Drive Num

The number of tape drives installed.

 

 

E/E Addr*

The element address of the entry/exit port.

 

 

Parity

Whether parity checking is enabled for the SCSI bus that is connected to

 

the library. When the parity option is enabled, the library checks all data

 

coming across the SCSI bus for parity.

 

 

Pty Retry

The number of times the library will retry a SCSI phase after detecting a

 

parity error.

 

 

Installation and Operation

97

Page 111
Image 111
Exabyte 440, 480 manual Scsi mode parameters