![](/images/new-backgrounds/1258421/258421267x1.webp)
Chapter 7
3.Refer to the table below for the element indexes. These numbers correspond to the library components and are necessary for some tests.
Library component | Element index |
|
|
Fixed cartridge slot | 0 |
|
|
Cartridge slots | Exabyte 440: 1 to 40 |
| Exabyte 480: 1 to 80 |
| (See Appendix D for entire |
| numbering scheme.) |
|
|
Tape drive 1 | 82 |
|
|
Tape drive 2 | 83 |
|
|
Tape drive 3 | 84 |
|
|
Tape drive 4 | 85 |
|
|
CHM | 86 |
|
|
Entry/exit port | 81 |
|
|
Performing diagnostic tests
1.From the Main Menu, select Maintenance Menu, then select Diagnostics Menu. A screen of diagnostics tests appears:
→ | S | e | l | f |
| T | e | s | t |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | o | s | i | t | i | o | n |
| t | o |
| E | l | e | m |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P | a | r | k |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| M | o | v | e |
| C | a | r | t | r | i | d | g | e |
|
| ↓ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2.Select one of the tests. (Each test is described in the following table.)
120 | Exabyte 440 and Exabyte 480 |