Library Operation
Replacing the cartridge magazines
To open the door and replace a data cartridge magazine:
1.Insert the key in the lock, push in, and turn it one quarter turn to the right, as shown in the following figure. When you unlock the door:
The library completes its current operation, moves the CHM to the home position at the bottom of the long axis, rotates the drum assembly to the home position, and turns off current to all motors.
The interlock mechanism releases.
➤Important Do not open the library door unless you need to remove and replace cartridge magazines or perform a maintenance operation. It takes 2½ to 5 minutes for the library to update the cartridge inventory after the door is opened and closed.
Installation and Operation | 79 |