| LCD Error Codes | |
|
|
| |
Error | Description | Corrective action | |
|
|
| |
| DRUM MOVE, SAXIS EXT. | Open the door and look for anything that | |
| The CHM could not move | might be obstructing the CHM along its short | |
| along the short axis. | axis. | |
101 |
| Make sure the library and tape drives are not | |
|
| being used by any host, then press >5HVHW@ on | |
|
| the operator panel. If the error persists, | |
|
| contact your service provider. | |
|
|
| |
| DRIVE DID NOT EJECT. The | There may be a problem with the tape drive. | |
104 | CHM timed out waiting for a | Contact your service provider. | |
| tape drive to eject a cartridge. |
| |
|
|
| |
| 480 KEY NOT PRESENT. The | Reseat the hardware key on the controller card | |
| library is missing the | at the rear of the library. | |
105 | hardware key. (This error | Make sure the library and tape drives are not | |
applies to the Exabyte 480 | |||
being used by any host, then press >5HVHW@. If | |||
| |||
| only.) | ||
| the error persists, contact your service | ||
|
| ||
|
| provider. | |
|
|
| |
| INVALID BOOT ROM. The | You do not have the correct boot ROM for the | |
108 | installed boot ROM is not | firmware you are trying to run in your library. | |
compatible with the flash | Contact your service provider. | ||
| |||
| EEPROM code. |
| |
|
|
| |
| CHECK CLEANER. The | Replace the cleaning cartridge and try | |
| cleaning cartridge was | cleaning the tape drive again. Make sure you | |
| ejected immediately after | are using the correct type of cleaning cartridge | |
109 | being loaded into the tape | for your tape drive. If the error persists, | |
| drive. | contact your service provider. | |
|
| Note: This error is only displayed if the | |
|
| cleaning was requested from the LCD. | |
|
|
| |
115 | EMPTY DRIVE SLOT. There is | Make sure that all tape drive slots have either | |
no tape drive in this drive slot. | a tape drive or a drive blank installed. | ||
| |||
|
|
|
Installation and Operation | 167 |