Appendix C

Error

Description

Corrective action

 

 

 

 

INTERFACE DISABLED. The

Make certain the library is in the correct

77

library was not in the correct

control mode. If it is, contact your service

control mode when the

provider.

 

 

operator sent a command.

 

 

 

 

 

E/E FAILED TO EXTEND. The

Open the door and look for obstructions

80

entry/exit port could not be

around the entry/exit transport arm. If there

 

extended.

are no obstructions, contact your service

 

 

provider.

 

E/E FAILED TO RETURN. The

 

 

81

entry/exit port could not be

 

 

retracted.

 

 

 

 

 

INVALID BLANK CONFIG. The

This error applies to earlier models of the

 

drive blank configuration is

library only. If you operate the library with

90

invalid.

fewer than four drives, you must have drive

 

blanks installed in the empty slots. Tape drives

 

 

 

 

must be installed in contiguous slots, starting

 

 

with the top slot.

 

 

 

 

OPERATOR ABORTED. A

No corrective action required.

91

diagnostic was aborted while

 

 

it was in progress.

 

 

 

 

 

DRIVE NOT INSTALLED. The

This error only appears on the Clean Drives

 

tape drive could not be

Menu. If no tape drive is installed in the

97

cleaned because no tape drive

location, redirect the CHM. If a tape drive is

is installed in this location.

installed, make sure that the drive carrier is

 

 

 

correctly seated. If the error persists, contact

 

 

your service provider.

 

 

 

 

NO MAGAZINE. There is no

If no magazine is installed in that location,

 

magazine installed in this

redirect the CHM. If a magazine is installed,

98

location.

make sure that it is correctly seated on the

 

 

mounting plate. If the error persists, contact

 

 

your service provider.

 

 

 

166

Exabyte 440 and Exabyte 480

Page 180
Image 180
Exabyte 480, 440 manual Operator ABORTED. a