Appendix C
Error | Description | Corrective action | |
|
|
| |
| INTERFACE DISABLED. The | Make certain the library is in the correct | |
77 | library was not in the correct | control mode. If it is, contact your service | |
control mode when the | provider. | ||
| |||
| operator sent a command. |
| |
|
|
| |
| E/E FAILED TO EXTEND. The | Open the door and look for obstructions | |
80 | entry/exit port could not be | around the entry/exit transport arm. If there | |
| extended. | are no obstructions, contact your service | |
|
| provider. | |
| E/E FAILED TO RETURN. The | ||
|
| ||
81 | entry/exit port could not be |
| |
| retracted. |
| |
|
|
| |
| INVALID BLANK CONFIG. The | This error applies to earlier models of the | |
| drive blank configuration is | library only. If you operate the library with | |
90 | invalid. | fewer than four drives, you must have drive | |
| blanks installed in the empty slots. Tape drives | ||
|
| ||
|
| must be installed in contiguous slots, starting | |
|
| with the top slot. | |
|
|
| |
| OPERATOR ABORTED. A | No corrective action required. | |
91 | diagnostic was aborted while |
| |
| it was in progress. |
| |
|
|
| |
| DRIVE NOT INSTALLED. The | This error only appears on the Clean Drives | |
| tape drive could not be | Menu. If no tape drive is installed in the | |
97 | cleaned because no tape drive | location, redirect the CHM. If a tape drive is | |
is installed in this location. | installed, make sure that the drive carrier is | ||
| |||
|
| correctly seated. If the error persists, contact | |
|
| your service provider. | |
|
|
| |
| NO MAGAZINE. There is no | If no magazine is installed in that location, | |
| magazine installed in this | redirect the CHM. If a magazine is installed, | |
98 | location. | make sure that it is correctly seated on the | |
|
| mounting plate. If the error persists, contact | |
|
| your service provider. | |
|
|
|
166 | Exabyte 440 and Exabyte 480 |