Appendix A

International 220 VAC Power Cord

￿The power cord must have an attachment plug of the proper type, rating, and safety approval for the intended country.

￿The power cord must have an IEC 320 female connector on one end.

￿The flexible cord must be harmonized to CENELEC publication HD-21. The electrical characteristics and rating must be minimum H05VVF3G0.75 (6 A).

SCSI terminator specifications

The SCSI terminator must match the SCSI bus configuration (single-ended, LVD, or HVD, and wide or narrow). In addition, all termination must be external. Do not use internal terminators to terminate the library or the tape drives.

To ensure proper performance of the library and tape drives, Exabyte recommends one of the following external terminators:

External terminator specifications

Narrow

Single-ended

AMP Amplimite 750381-1

 

 

 

 

HVD

AMP Amplimite 796051-1

 

 

 

Wide

LVD

AMP Amplimite 796051-1

 

 

 

 

HVD

AMP Amplimite 869515-1

 

 

 

Note: For best results on a single-ended bus, use active termination.

Exabyte testing has shown that older passive termination does not provide rising edge transitions that are fast or clean enough at fast SCSI speeds.

148

Exabyte 440 and Exabyte 480

Page 162
Image 162
Exabyte 480, 440 manual Scsi terminator specifications, International 220 VAC Power Cord, External terminator specifications