RESTRICTED USE ONLY

FARGO Electronics, Inc.

Reviewing Tracks 1, 2, and 3 (in Table format)

Review this Table, which displays the SS, ES, FS, and the valid characters defined for each Track.

 

Start

End

Field

Valid Characters

Maximum

 

Sentinel

Sentinel

Separator

 

Number of

 

 

 

 

 

Characters

 

 

 

 

 

 

Track 1

%

?

^

0-9, A-Z, Punct.

78

 

 

 

 

(ASCII 32-95)

 

 

 

 

 

(See the Table below.)

 

 

 

 

 

 

 

Track 2

;

?

=

0-9, ;, =, ?

39

 

 

 

 

(ASCII 48-63)

 

 

 

 

 

(See the Table below.)

 

 

 

 

 

 

 

Track 3

;

?

=

0-9, ;, =, ?

106

 

 

 

 

(ASCII 48-63)

 

 

 

 

 

(See the Table below.)

 

 

 

 

 

 

 

Reviewing the Track Data Note

Review this Table, which displays how Track Data should be entered for Tracks 1, 2, and 3.

Track

Data Entry

 

 

Sending data to Track 1

~1%JULIE ANDERSON^623-85-1253?

 

 

Sending data to Track 2

~2;0123456789?

 

 

Sending data to Track 3

~3;0123456789?

 

 

PersonaC25 Card Printer User Guide (Rev. 4.0)

118

 

Page 118
Image 118
FARGO electronic S000256 manual Reviewing Tracks 1, 2, and 3 in Table format, Reviewing the Track Data Note