FARGO electronic S000256 manual Sensor Calibration, Calibrating the Color Ribbon Sensor

Models: S000256

1 181
Download 181 pages 57.44 Kb
Page 77
Image 77
Sensor Calibration

RESTRICTED USE ONLY

FARGO Electronics, Inc.

Sensor Calibration

Calibrating the Color Ribbon Sensor

Symptom: There are problems with the color ribbon skipping panels or the incorrect colors being applied to the card, requiring calibration of the Ribbon Sensor. Be certain to shade the Printer from direct sources of light (e.g., the sun, florescent or incandescent lamps).

Steps Procedure

1 Remove the back cover of the Printer and locate the DIP switches on the Main Circuit Board.

2 Set DIP switches 1, 2 and 3 to the ON position.

3 Align the color ribbon on the clear or yellow panel over the light-emitting portion of the Ribbon Sensor.

4 Close both Top Cover of the Printer.

5 Run the self-test procedure. See the Performing the Standard Self Test procedure on page 57.

6 After the Flipper Table rotates, two long beeps from the Printer will sound to indicate that the Ribbon Sensor calibration is completed.

7 Remove the power plug from the Printer.

Continued on the next page

Fargo Electronics

PN # xxxxxx

Rev. X

PersonaC25 Card Printer User Guide (Rev. 4.0)

77

 

Page 77
Image 77
FARGO electronic S000256 manual Sensor Calibration, Calibrating the Color Ribbon Sensor, Continued on the next page