RESTRICTED USE ONLY

FARGO Electronics, Inc.

Magnetic Offset Adjustment

Using the Magnetic Offset (RP7 Potentiometer location)

Step

Procedure

1Use magnetic developer spray or a Magnetic Stripe viewer to measure the location of the start sentinel on an encoded card to accurately calibrate the RP7 potentiometer.

2Use the Magnetic Self Test to generate test samples. See the Performing the Standard Self Test procedure on page 57.

DARKNESS

Rp7 OFFSET PRN

Rp6

Rp1

OFFSET MAG RP3

OFFSET LAM

Tp3

Tp5

COLOR

PersonaC25 Card Printer User Guide (Rev. 4.0)

72

 

Page 72
Image 72
FARGO electronic S000256 manual Magnetic Offset Adjustment, Using the Magnetic Offset RP7 Potentiometer location