system ha on-failure

set

system ha on-failure

Use this command to control the behavior of a FortiMail unit in an active-passive HA group when remote service monitoring detects a failure. In most cases you should set On Failure to wait for recovery and then assume slave role. In this mode when service monitoring detects a failure the FortiMail unit effective operating mode changes to FAILED. In FAILED mode the FortiMail unit and can automatically recover, switch to the SLAVE effective operating mode and synchronize MTA spool directories with the other FortiMail unit which should be operating in the MASTER effective operating mode.

Syntax

set system ha on-failure {off restore slave}

Keywords/Variables

Description

Default

 

 

 

off

After a failure the FortiMail unit effective operating mode changes to

 

 

OFF. The FortiMail unit will not process mail or join the HA group until

 

 

you manually change the FortiMail unit effective operating mode to

 

 

MASTER (primary) or SLAVE (backup).

 

 

 

 

restore

Similar to slave the FortiMail unit effective operating mode changes to

 

 

FAILED when remote service monitoring detects a failure. However, in

 

 

this case on recovery the failed FortiMail unit effective operating mode

 

 

switches back to its configured operating mode. This behavior may be

 

 

useful in some scenarios but may cause problems in others.

 

 

 

 

slave

The FortiMail unit effective operating mode changes to FAILED when

 

 

remote service or local network interface service monitoring detects a

 

 

failure. In FAILED mode the FortiMail unit uses remote service

 

 

monitoring to attempt to connect to the other FortiMail unit in the HA

 

 

group (which should be operating as the primary unit with effective

 

 

operating mode of MASTER). If you fix the problem that caused the

 

 

failure the failed FortiMail unit recovers by changing its effective

 

 

operating mode to SLAVE. The failed FortiMail unit then synchronizes

 

 

the content of its MTA spool directories to the FortiMail unit operating as

 

 

the primary unit. The primary unit can then deliver this email.

 

 

 

 

Example

Enter the following command to configure a FortiMail unit to switch to FAILED effective operating mode and when restored, to change the effective operating mode to SLAVE.

set system ha on-failure slave

History

FortiMail v3.0 MR2 New.

Related topics

set system ha config

set system ha {cpeer interface peer secondary-interface secondary-peer}

set system ha data

set system ha datadir

set system ha lservice

set system ha mode

set system ha monitor

set system ha passwd

set system ha remote-as-heartbeat

set system ha {restart restore resync}

set system ha rservice

set system ha takeover

 

FortiMail™ Secure Messaging Platform Version 3.0 MR4 CLI Reference

324

06-30004-0420-20080814

Page 324
Image 324