system ha monitor | set |
system ha monitor
Use this command to configure how the FortiMail HA daemon sends HA heartbeat packets to detect if the primary unit has failed. If the backup unit detects that the primary unit has failed, the backup unit effective operating mode changes to master and the backup unit becomes the primary unit.
Note: Use the set system ha config command to configure HA daemon settings. Other HA daemon configuration commands include “set system ha config” on page 313, “set system ha data” on page 318, “set system ha datadir” on page 319, and “set ” on page 324.
In most cases you do not have to change heartbeat settings. The default settings mean that if the primary unit fails, the backup unit switches to being the primary unit after 3 x 5 or about 15 seconds; resulting in a failure detection time of 15 seconds.
If the failure detection time is too long the primary unit could fail and a delay in detecting the failure could mean that email is delayed or lost. Decrease the failure detection time if email is delayed or lost because of an HA failover.
If the failure detection time is too short the backup unit may detect a failure when none has occurred. For example, if the primary unit is very busy processing email it may not respond to HA heartbeat packets in time. In this situation, the backup unit may assume that the primary unit has failed when the primary unit is actually just busy. Increase the failure detection time to prevent the backup unit from detecting a failure when none has occurred.
Syntax
set system ha monitor <heartbeat_port_integer> <heartbeat_time_integer> <retries)integer>
Keywords/Variables | Description | Default |
|
|
|
<heartbeat_port_integer> | The TCP port used for HA heartbeat communications. | 20000 |
<heartbeat_time_integer> | The time between which the FortiMail units in the HA group | 5 |
| send HA heartbeat packets. The default test interval between |
|
| HA heartbeat packets is 5 seconds. The test interval range is 2 |
|
| to 60 seconds. Heartbeat packets are sent at regular intervals |
|
| so that each FortiMail unit in an |
|
| confirm that the other unit n the group is functioning. If the |
|
| primary unit detects that the backup unit has failed the primary |
|
| unit continues to operate normally. If the backup unit detects |
|
| that the primary unit has failed, the HA effective operating mode |
|
| of the backup unit changes to master and the back up unit |
|
| becomes the primary unit. |
|
|
|
|
<retries_integer> | The number of consecutive times the HA heartbeat detects a |
|
| failure before the backup unit decides that the primary unit has |
|
| failed. |
|
| The number of times the check fails range is 1 to a very high |
|
| number. Set the number of times the check fails to 0 to disable |
|
| interface monitoring or hard drive monitoring. |
|
|
|
|
Example
Enter the following command to change the HA heartbeat configuration so that each FortiMail unit in the HA group send heartbeat packets every 20 seconds and the FortiMail units in the HA group detect a failure if the HA heartbeat check fails 5 times. This command keeps the HA heartbeat TCP port set to 20000.
set system ha monitor port 20000 20 5