7.4.4Details of Supported Traps

Please refer to Section 7.4.4 in Commonality.

SPARC64 V Implementation-Specific Traps

SPARC64 V supports the following implementation-specific trap type:

async_data_error

7.5Trap Processing

Please refer to Section 7.5 of Commonality.

7.6Exception and Interrupt Descriptions

Please refer to Section 7.6 of Commonality.

7.6.4SPARC V9 Implementation-Dependent, Optional Traps That Are Mandatory in SPARC JPS1

Please refer to Section 7.6.4 of Commonality.

SPARC64 V implements all six traps that are implementation dependent in SPARC V9 but mandatory in JPSI (impl. dep. #35). Se Section 7.6.4 of Commonality for details.

7.6.5SPARC JPS1 Implementation-Dependent Traps

Please refer to Section 7.6.5 of Commonality.

SPARC64 V implements the following traps that are implementation dependent (impl. dep. #35).

async_data_error [tt = 04016] (Preemptive or disrupting) (impl. dep. #218) — SPARC64 V implements the async_data_error exception to signal the following errors.