Uncorrectable errors in the internal architecture registers (general registers–gr, floating-point registers–fr, ASR, ASI registers)

Uncorrectable errors in the core pipeline

System data corruption

Watch dog timeout first time

TLB access error upon access by an ldxa or stxa instruction

Multiple errors may be reported in a single generation of the async_data_error exception. Depending on the situation, the async_data_error trap becomes a precise trap, a disrupting trap, or a preemptive trap upon error detection. The TPC and TNPC stacked by the exception may indicate the exact instruction, the preceding instruction, or the subsequent instruction inducing the error. See Appendix P for details of the async_data_error exception in SPARC64 V.

40 SPARC JPS1 Implementation Supplement: Fujitsu SPARC64 V • Release 1.0, 1 July 2002