Fujitsu Fujitsu SPARC64 V manual ASIASYNCFAULTADDRU2 register is described in Table P-17, Syndrome

Models: Fujitsu SPARC64 V

1 255
Download 255 pages 53.5 Kb
Page 189
Image 189

P.7.3 ASI_ASYNC_FAULT_ADDR_U2

[1]Register name:

[2]ASI:

[3]VA:

[4]Error checking:

[5]Format & function:

[6]Initial value at reset:

[7]Update:

[8]Software access:

ASI_ASYNC_FAULT_ADDR_U2 (ASI_AFAR_U2)

4D16

0816 Parity

See TABLE P-17.

Hard POR: All fields are set to 0.

Other reset: Values are unchanged.

When a new restrainable error is detected, ASI_AFAR_U2 is updated as defined in Section P.7.1 in the notes on the AFSR Prio_U2 column of TABLE P-15.

When a program writes to ASI_AFAR_U2, all fields in ASI_AFAR_U2 are set to 0 and validated.

ldxa [%g0]ASI_AFAR_U2,%rN

stxa %g0, [%g0]ASI_AFAR_U2

Write to ASI_AFAR_U2 after read is expected.

The ASI_ASYNC_FAULT_ADDR_U2 register is described in TABLE P-17.

TABLE P-17ASI_ASYNC_FAULT_ADDR_U2 (ASI_AFAR_U2) Register Bit Description

Bit

Name

R/W

Description

 

 

 

 

63:56

CONTENTS

R

Contents of ASI_AFAR_U2. This field has the following two functions:

 

 

 

• Indicates the type of error held in the other fields of ASI_AFAR_U2 as

 

 

 

defined in TABLE P-15.

 

 

 

• Controls the recording of newly detected restrainable errors. Upon the

 

 

 

detection of a new restrainable error recordable in ASI_AFAR_U2, if the

 

 

 

current ASI_AFAR_U2.CONTENTS < the AFSR Prio_U2 value of the new

 

 

 

error, the new error is recorded into ASI_AFAR_U2. If the current

 

 

 

ASI_AFAR_U2.CONTENTS ≥ the AFSR Prio_U2 value of the new error, the

 

 

 

error is not recorded in ASI_AFAR_U2 and ASI_AFAR_U2 is unchanged.

55:48

SYNDROME

R

Syndrome of incoming data at L2$ fill. When ASI_AFAR_U2.CONTENTS

 

 

 

indicates CE_INCOMED or UE_L2$FILL, this field indicates the syndrome of

 

 

 

the doubleword with error incoming from UPA bus. Otherwise, this field

 

 

 

indicates the unpredictable value.

 

 

 

 

178 SPARC JPS1 Implementation Supplement: Fujitsu SPARC64 V • Release 1.0, 1 July 2002

Page 189
Image 189
Fujitsu Fujitsu SPARC64 V manual ASIASYNCFAULTADDRU2 register is described in Table P-17, Syndrome