Fujitsu Fujitsu SPARC64 V manual Following actions are executed in this order, State transition

Models: Fujitsu SPARC64 V

1 255
Download 255 pages 53.5 Kb
Page 180
Image 180

The following actions are executed in this order:

a. State transition

if (TL = MAXTL), the CPU enters error_state and abandons the ADE trap;

else if (CPU is in execution state && (TL = MAXTL − 1)), then the CPU enters RED_state.

b. Trap target address calculation

When the CPU is in execution state, trap target address is calculated by %tba, %tt, and %tl.

Otherwise, the CPU is in RED_state and the trap target address is set to

RSTVaddr + A016.

c. TL is incremented: TL TL + 1.

3.Save the old value into TSTATE, TPC, and TNPC.

PSTATE, PC, and NPC immediately before the ADE trap are copied into TSTATE, TPC, and TNPC, respectively. If the copy source register contains an uncorrectable error, the copy target register also contains the UE.

4.Set the specific register setting:

The following three sets of registers are updated:

a.Update and validation of specific registers. Hardware writes the registers listed in TABLE P-12.

TABLE P-12Registers Written for Update and Validation

Register

Condition For Writing

Value Written

 

 

 

PSTATE

Always

AG = 1, MG = 0, IG = 0, IE = 0, PRIV = 1, AM = 0, PEF = 1,

 

 

RED = 0 (or 1 depending on the CPU status), MM = 00, TLE = 0,

 

 

CLE = 0.

PC

Always

nPC

Always

CCR

When the register contains UE

FSR, GSR

When the register contains UE

ADE trap address. ADE trap address + 4. 0.

If either FSR or GSR contains a UE, 0 is written to that register. When 0 is written to FSR and/or GSR upon a single- ADE trap, ASI_UGESR.IUG_%F is set to 1.

CWP, CANSAVE, When the register contains UE

Any register among CWP, CANSAVE, CANRESTORE,

CANRESTORE,

OTHERWIN, and CLEANWIN that contains a UE is written to 0.

OTHERWIN,

When 0 is written to one of these registers upon a single-ADE

CLEANWIN

trap, ASI_UGESR.IUG_PSTATE = 1 is set to 1.

 

 

The error(s) in a written register are removed by setting the correct value to the error checking (parity) code during the full write of the register.

Release 1.0, 1 July 2002

F. Chapter P Error Handling 169