to a volume that only uses 9 GB of capacity on each disk drive, the remaining 27 GB of capacity on the disk drive is unusable.

The disk identified by the first SCSI ID on the command line is assigned as the primary disk drive when creating an IM volume. If the SAS controller is allowed to resync the disk drives, the data on the primary disk drive is available by accessing the newly created volume.

Using the AUTO Command

The AUTO command automatically creates an IM volume on the SAS controllers. The volume is created with the maximum number of disks available for use in the specified volume type. The main difference from the CREATE command is that with AUTO command user does not specify SCSI ID values for disks to use in the volume. The cfggen utility automatically uses the first disks it finds that are usable in the IM volume. Firmware and hardware limitations for the family of controllers limit the number of configurations that are possible.

Syntax

cfggen <controller #> auto <volume type> <size> [qsync] [noprompt]

Parameters

 

<volume type>

Volume type for the volume to be created. Valid value is IM.

<size>

Size of the RAID volume in Mbytes or “MAX” for the maximum size

 

available.

[qsync]

Quick synchronization of the volume created.

[noprompt]

Eliminates warnings and prompts.

Operation

When AUTO creates an IM volume, the first disk found is assigned as the primary disk drive. If the controller is allowed to resync the disk drives, the data on the primary disk drive is available by accessing the newly created volume. Reply Yes if you want to complete the creation.

HOTSPARE

The HOTSPARE command creates a hot spare disk drive. The hot spare drive is added to hot spare pool 0.

Syntax

cfggen <controller #> HOTSPARE [DELETE] <Encl:Bay>

Parameters

 

<controller #>

A SAS controller number between 0 and 255.

[DELETE]

Specifies that the hot-spare is to be deleted (Omit the DELETE keyword

 

to specify hot-spare creation).

<Encl>:<Bay>

Enclosure number and Bay number that identifying the disk drive that

 

will become the hot spare.

Operation

The number of disk drives in an IM array plus the hot spare disk cannot exceed three. You can create only one hot spare disk. You must make sure the capacity of the hot spare disk is greater

108 Installing the System