| • Running Disparity Errors - Number of dwords with running |
| disparity errors that have been received outside of PHY reset |
| sequences, since the last PHY Link Error Reset.a |
| • PHY Reset Errors - Number of times the PHY reset sequence |
| has failed, since the last PHY Link Error Reset.a |
Link Error Count | Actual link error count values since the last PHY Link Error Reset.a |
Threshold Count | Link error count threshold values.b |
Threshold Time | Time, in seconds, over which to apply Threshold Count.b |
a. The count stops when it reaches the maximum value.
b. When a Link Error Count exceeds a Threshold Count within the Threshold Time the link rate may be reduced by the MPT firmware.
Exit the SAS Configuration Utility Screen
As some changes only take effect when you exit the utility, it is important to always exit the utility properly. To exit the utility, follow these steps:
1.To return to the Adapter List from Adapter Properties, press ESC.
2.To exit the utility from the Adapter List, press ESC.
NOTE: A similar exit screen is used when exiting most other screens, and can be used to save settings.
The exit screen shows some options that are grey, indicating that they are not available. You can only select the available options. The exit choices are as follows:
•Are you sure you want to exit?
•Cancel Exit
•Save changes and reboot
•Discard changes and reboot
•Exit the Configuration Utility and Reboot
CFGGEN Utility
The CFGGEN utility is a command line utility that runs in the Linux, EFI, and Windows
Starting CFGGEN
TheCFGGENutility is located on the HP IPF Offline Diagnostic and Utilities CD. To use CFGGEN, follow these steps:
1.Insert the CD into the drive.
2.Boot the system to the EFI Shell prompt.
3.From the EFI Shell prompt, change to the CD drive.
shell> fs0: Enter fs0:\>
4.Change to the directory that containscfggen.efi.
fs0:\> cd EFI\HP\TOOLS\NETWORK Enter fs0: EFI\HP\TOOLS\NETWORK>
From this directory use CFGGEN.
HP 8 Internal Port SAS HBA (SAS Controller) 299