• Running Disparity Errors - Number of dwords with running

 

disparity errors that have been received outside of PHY reset

 

sequences, since the last PHY Link Error Reset.a

 

• PHY Reset Errors - Number of times the PHY reset sequence

 

has failed, since the last PHY Link Error Reset.a

Link Error Count

Actual link error count values since the last PHY Link Error Reset.a

Threshold Count

Link error count threshold values.b

Threshold Time

Time, in seconds, over which to apply Threshold Count.b

a. The count stops when it reaches the maximum value.

b. When a Link Error Count exceeds a Threshold Count within the Threshold Time the link rate may be reduced by the MPT firmware.

Exit the SAS Configuration Utility Screen

As some changes only take effect when you exit the utility, it is important to always exit the utility properly. To exit the utility, follow these steps:

1.To return to the Adapter List from Adapter Properties, press ESC.

2.To exit the utility from the Adapter List, press ESC.

NOTE: A similar exit screen is used when exiting most other screens, and can be used to save settings.

The exit screen shows some options that are grey, indicating that they are not available. You can only select the available options. The exit choices are as follows:

Are you sure you want to exit?

Cancel Exit

Save changes and reboot

Discard changes and reboot

Exit the Configuration Utility and Reboot

CFGGEN Utility

The CFGGEN utility is a command line utility that runs in the Linux, EFI, and Windows Pre-Installation (WinPE) environments. It is a minimally interactive program that you execute from a command line prompt, or a shell script. The results from invoking this utility are communicated through the program status value that is returned when the program exits. Use the CFGGEN utility to create IM storage configurations on SAS controllers. Some CFGGEN commands work only with SAS adaptors in the EFI environment.

Starting CFGGEN

TheCFGGENutility is located on the HP IPF Offline Diagnostic and Utilities CD. To use CFGGEN, follow these steps:

1.Insert the CD into the drive.

2.Boot the system to the EFI Shell prompt.

3.From the EFI Shell prompt, change to the CD drive.

shell> fs0: Enter fs0:\>

4.Change to the directory that containscfggen.efi.

fs0:\> cd EFI\HP\TOOLS\NETWORK Enter fs0: EFI\HP\TOOLS\NETWORK>

From this directory use CFGGEN.

HP 8 Internal Port SAS HBA (SAS Controller) 299