4.Pull the fan straight up and out of the chassis.

CAUTION: To prevent server components from overheating, replace the fan within 20 seconds. Failure to observe this caution results in the server automatically shutting down to prevent an overtemperature condition.

Figure 6-5 Removing and Replacing a Hot-Swappable Chassis Fan Unit

Fan Unit 1

Fan Unit 2

Fan Unit 3

Replacing a Hot-Swappable Chassis Fan Unit

CAUTION: To prevent server components from overheating, replace the fan within 20 seconds. Failure to observe this caution results in the server automatically shutting down to prevent an overtemperature condition.

NOTE: The fan unit is keyed to fit into the fan housing in the correct orientation only.

To replace a hot-swappable chassis fan unit, follow these steps:

1.Push the fan unit firmly into the fan housing until it is flush with the top of the chassis.

NOTE: It can take up to ten seconds after installation for the new fan LED to turn off.

2.Check the diagnostic LED that corresponds to the replaced fan unit.

Removing and Replacing a Hot-Swappable Chassis Fan Unit 185