DISABLEIR
The DISABLEIR command turns off IR functionality on a SAS controller. To accomplish the disabling, set the MPI_IOUNITPAGE1_DISABLE_IR bit in the IO Unit 1 MPT Configuration page.
Syntax
cfggen <controller #> disableir
Parameters
This command does not require <controller #>.
Sample Output
Vendor Device
Index ID ID Bus Device
-----
0 1000h 0054h 14h 08h LSI 1068 SAS Host Adapter
LOCATE
The LOCATE command turns locate LED's on and off.
Syntax
cfggen <controller #> locate
Parameters
<controller #> | A SAS controller number between 0 and 255. |
Smart Array P400, P600 and P800 Controllers
The following information is provided to assist you in configuring the Smart Array P400, P600 and P800 controllers during installation. For additional information refer to the following documents:
•HP Smart Array P400 Controller Support Guide
•HP Smart Array P600 Controller for Integrity Servers User Guide
•HP Smart Array P800 Controller for Integrity Servers User Guide
Quick Installation Procedure
To install the controller, follow these steps:
1.Power off the server.
2.Install additional physical drives if necessary (see “Connecting External Storage” (page 109)). The number of drives in the server determines the RAID level that is auto configured when the server is powered on.
3.Power on the server.
4.Update the controller firmware (see “SAUPDATE Utility” (page 110)). When the firmware update process is complete, the server reboots and runs through a POST procedure. This POST procedure halts briefly during controller initialization and prompts you to open ORCA (Option ROM Configuration for Arrays).
5.Open ORCA. See “Configuring the Array” (page 115).
•If using a headless console, press Esc+8.
•Otherwise, press F8.
6.Configure the logical boot drive, and exit from ORCA.
Depending on the OS, additional device drivers and management agents must be installed. See the User Guide for the specific HP Smart Array Controller at:
306 Core I/O Card Utilities