IMPORTANT: For cooling purposes, always leave disk drive fillers in slots that do not contain a disk drive.
Removing a
To remove a
1.Squeeze the tabs on the front of the filler to release it from the slot in the drive bay.
2.Pull gently until the filler slides out of the chassis.
Replacing a
To replace a
1.Orient the disk drive filler so that the release tab is on the left side of the filler and the airflow holes are on the right side of the filler.
2.Insert the filler into the slot guides, and slide the filler into the slot until it clicks into place and is fully seated.
Installing aThere are eight
CAUTION: Drives are loaded in the factory, starting with number 8, working from right to left and bottom to top. If you have never changed your SAS configuration before, you can safely move SAS devices downwards as a block. If you have bays 6, 7, and 8 occupied you can move them down to bays 1, 2, and 3 without having the hardware paths change during a
CAUTION: A
TIP: When you receive an HP Integrity rx3600 or HP Integrity rx6600 server from HP, if you ever plan to add other SAS devices into the system, you should consider moving the SAS devices so they start in bay 1 going upwards instead of Bay 8 going downwards.
Installing a
NOTE: The replacement disk drive must have the same product number as the disk drive that you replace.
To install a
1.Use Figure
2.Remove the disk drive filler if required. See “Removing a
60 Installing the System