10.Power up to EFI. See “Powering On and Powering Off the Server” (page 93) for this procedure.
a.Verification from EFI
1.Respond YES to prompts regarding copying information onto the new board.
2.Verify the serial number and model string data information copied onto the new I/O board.
a.Boot to EFI.
b.Enter service mode using the following command:
Shell> sysmode service Current System Mode: ADMIN You are now in SERVICE mode.
c.Use the sysset command to verify that all values are set:
Shell> sysset
System Information: Manufacturer: hp
Product Name: server rx3600
Product Number: AB463A
Secondary Product Number is Identical Serial number: SGH43442VB Secondary Serial Number is Identical
UUID:
Product ID: 0x301
b.Enable the TPM.
1.Access the EFI Shell.
2.Enter info sec to display the server security settings on the screen. The TPM is disabled by default.
3.Enter secconfig to display a list of configurable security settings.
4.Enter secconfig tpm on to enable the TPM.
c.Verify the system board replacement and operation using either the iLO 2 MP or EFI commands.
11.Viewing Warnings
To view warning access the EFI shell and run the info warning command.
12.Verifying I/O cards
To verify the I/O cards access the EFI shell and run the info io command.
Shell> info io
I/O INFORMATION
BOOTABLE DEVICES
Order Media Type Path
-----
1 | CDROM | Acpi(HWP0002,PNP0A03,0)/Pci(21)/Usb(0, 0)/CDROM(Entry0)/HD(Part1,Sig00000000) |
2 | HARDDRIVE |
|
3 HARDDRIVE
4 HARDDRIVE
Seg | Bus | Dev | Fnc | Vendor | Device Slot |
| |
# | # | # | # | ID | ID | # | Path |
00 | 00 | 01 | 00 | 0x103C | 0x1303 | XX | Acpi(HWP0002,PNP0A03,0)/Pci(10) |
00 | 00 | 01 | 01 | 0x103C | 0x1302 | XX | Acpi(HWP0002,PNP0A03,0)/Pci(11) |
00 | 00 | 01 | 02 | 0x103C | 0x1048 | XX | Acpi(HWP0002,PNP0A03,0)/Pci(12) |
I/O Backplane Upgrade 267