•When the fan is functioning normally, the LED is off.
•If the fan fails, the LED is lit.
3.Replace the server top cover. See “Replacing the Top Cover” (page 182).
Removing and Replacing a Hot-Swappable Power Supply
The server can have one or two
CAUTION: Observe all ESD safety precautions before removing or replacing a power supply. Failure to follow ESD safety precautions can result in damage to the server.
NOTE: A
The dc power to the server does not have to be off to install or replace a
Power Supply Loading Guidelines
The supported configuration of the server requires a minimum of one power supply installed in slot P0 or slot P1. You can install a second, optional
CAUTION: When a second power supply is not used, the empty power supply slot must remain covered with the supplied metal filler panel. Failure to observe this caution can result in damage due to overheating if the cover does not remain in place.
CAUTION: Install the
Removing a Hot-Swappable Power Supply
To remove a
1.Move the cable management arm from the rack slide nearest the power supplies just enough to allow access to the power supplies.
2.Remove the power cord plug from the power supply receptacle.
3.Grasp the handle and push the locking tab down with your thumb to release the power supply from the socket on the midplane board.
4.Support the power supply with both hands, and pull the power supply out of the server (Figure
186 Removing and Replacing Server Components