Dimensions and Values
Table
Table
Dimension | Value |
|
|
Server weight (loaded product weight range | |
estimate) |
|
|
|
Rack |
|
|
|
Rack dimensions (depth x width x height) | 69.6 cm (27.4 in.) x 44 cm (17.32 in.) x 17.24 cm (6.8 in.) |
|
|
Rack weight | Max: 45.36 kg. (100 lbs.) |
|
|
Rack unit | Server takes up 4U in a rack |
|
|
Pedestal |
|
|
|
Pedestal dimensions (depth x width x height) | 69.2 cm (27.2 in.) x 36.9 cm (14.5 in.) x 51.2 cm (20.2 in.) |
|
|
Pedestal weight | 10.9 kg (24 lbs.) |
|
|
Minimum standalone configuration | 44.9 kg. (99 lbs.) |
|
|
Maximum standalone configuration | 51.7 kg. (114 lbs.) |
|
|
Grounding
The site building shall provide a safety ground/protective earth for each AC service entrance to all cabinets.
Install a PE (protective earthing) conductor that is identical in size, insulation material, and thickness to the
Electrical Specifications
This section provides electrical specifications for the HP server.
System Power Specifications
Available power (output) is the maximum dc power that the power supply can supply to the system.
Maximum input power is what the power supply requires from the AC line to deliver that maximum DC output (given worst case efficiency and max loading)
Maximum input current is the worst case/highest current given the lowest input voltage and the maximum input power
Table
Parameter | Rating |
|
|
|
|
ac Voltage | ||
|
|
|
Maximum dc Output Power | 1200 W | 1200 W |
|
|
|
Maximum System Input Current | 14 A1 | 7A1 |
Input frequency | 47 to 63 Hz | 47 to 63 Hz |
|
|
|
48 System Specifications